Oil immersed distribution transformer
Oil immersed distribution transformer product description: ZTelec specializes in producing Oil immersed distribution transformer is equipped characters as low loss, low noise, strong protection for thunder and lighting, well anti-shortcut capacity ……
Oil immersed distribution transformer product description:
ZTelec specializes in producing Oil immersed distribution transformer is equipped characters as low loss, low noise, strong protection for thunder and lighting, well anti-shortcut capacity and fine appearance etc.
Oil immersed distribution transformer production video:
Oil immersed distribution transformer warehouse:
Oil immersed distribution transformer Introduction:
Oil immersed distribution transformer developed by the ZTelec has the advantages of low loss, low noise and high efficiency and can achieve good energy-saving effect and reduce pollution. Compared with common oil-immersed transformer, it is unnecessary for full-sealed transformer to be equipped with oil conservator and change in oil volume is automatically adjusted and compensated by elasticity of corrugated sheet of corrugated tank,and transformer is isolated from air to prevent and slow down oil degrading and insulation aging, enhance operational reliability, with normal operation and no maintenance.
Oil immersed distribution transformer parameter:
Rated Capacity (KVA) |
LV(KV) | Connection Group | Short Circuit Resistance(%) | No Load Loss (W) |
Load Loss 75℃(W) |
No Load Current (%) |
30 | 0.4 | Yyn0
Dyn11 |
4 | 100 | 600 | 2.1 |
50 | 130 | 870 | 2.0 | |||
80 | 180 | 1250 | 1.8 | |||
100 | 200 | 1500 | 1.6 | |||
125 | 240 | 1800 | 1.5 | |||
160 | 280 | 2200 | 1.4 | |||
200 | 340 | 2600 | 1.3 | |||
250 | 400 | 3050 | 1.2 | |||
315 | 480 | 3650 | 1.1 | |||
400 | 570 | 4300 | 1.0 | |||
500 | 680 | 5100 | 1.0 | |||
630 | 4.5 | 810 | 6200 | 0.9 | ||
800 | 980 | 7500 | 0.8 | |||
1000 | 1150 | 1030 | 0.7 | |||
1250 | 1360 | 1280 | 0.6 | |||
1600 | 1640 | 1450 | 0.6 | |||
2000 | 1960 | 1980 | 0.6 | |||
2500 | 1310 | 2300 | 0.6 |
Oil immersed distribution transformer advantage:
1.The Oil immersed distribution transformer core is stacked by imported high-quality cold-rolled silicon steel sheet, which reduces no-load current greatly, and makes the core bound to ensure compactness of the core and reduce noise.
2.High-low voltage winding is wound with oxygen-free cooper, low-voltage winding of 500kVA and below adopts double layer cylinder structure, that of 630kVA and above adopts double helix and four helix structure, and high-voltage winding adopts mutilayer cylinder structure.
3.Transformer winding connection adopts Dyn11 to reduce influences of harmonic wave on the power grid and improve power supply quality.
4.The transformer is of full-sealed structure to prolong the shelf life and avoid suspended core use and maintenance.
5.The measured noise level is below the standard.
Oil immersed distribution transformer FAQ:
Q1: What is the MOQ ?
A1: 1 set.
Q2: Can we put/show our own Logo on your products?
A2: Yes.
Q3: What is the Terms of Payment?
A3: T/T,L/C,PAYPAL.(To make your money in safe ,please do payment via Alibaba trade assurance,if there is problem on quality ,Alibaba will return your money).
Q4: Can you offer Form E or C/O ?
A4: Yes, no problem, we can apply for it from our local government.
Q5: How is the delivery time ?
A5: It depends your order quantity and it normally takes 5-20 days .
Q6: How long is the service life ?
A6: It is 20-30 years.