Dry type rectifier transformer
The dry type rectifier transformer was born in response to market demand, which is a new type of transformer product. The dry phase shifting rectifier transformer has been developing in the direction of serialization. At the same time, in order to ……
The dry type rectifier transformer was born in response to market demand, which is a new type of transformer product. The dry phase shifting rectifier transformer has been developing in the direction of serialization. At the same time, in order to reduce the harmonic content, the phase number of the phase shifting rectifier transformer is more and more, and its capacity is also developed to a high level. In the process, new technology is used to improve the mechanical strength of the winding and the resistance to moisture, dirt, fire and radiation, and to enhance the ability to resist sudden short circuit. The stepped step core joint technology is used to reduce noise.
At the same time, more attention is paid to computer optimization design, which makes transformers more energy-efficient, and increases research on intelligence, and strives to make transformers have functions such as data processing, state control, and status display.
Dry type rectifier transformer production video:
This video shows the dry type rectifier transformer, which can clearly see the the appearance and details of the transformer.
Dry type rectifier transformer parameter:
Rated Capacity (KVA) |
Rated Voltage | Output Voltage×
Group Number |
Phase Shifting Angle | Insulation Grade | Reference Dimension
(L×W×H) |
Reference Weight
(KG) |
315 | 6KV+5%
or 10KV+5% |
690V×15 or others | 0°,12°,24°,36°,48°
or others |
H Class | 1480×820×1340 | 1320 |
400 | 1480×820×1420 | 1500 | ||||
500 | 1530×820×1510 | 1750 | ||||
630 | 1530×820×1580 | 2100 | ||||
800 | 1590×940×1650 | 2450 | ||||
1000 | 1680×920×1760 | 2950 | ||||
1250 | 1710×920×1765 | 3400 | ||||
1600 | 1780×940×1870 | 4250 |
Dry type rectifier transformer production display:
Dry type rectifier transformer FAQ:
1.What is the transformer capacity? How much KVA?
A: We supply 315, 400, 500, 630, 800, 1000, 1250, 1600kva, etc.
2.What’s the insulation grade?
A: H Class
3.What about the tap steps?
A: ±5%
4.Winding material requirements?
A: Copper, aluminum two options
5.What’s the phase shifting angle?
A: 0°,12°,24°,36°,48° or according to customers’ requirements
Dry type rectifier transformer certificate:
In 2011, we obtained the certificates of ISO9001:2008 International Quality Management System, and ISO14001 organization environmental management system. Products including Power Distribution Cabinet, HV Switchgear, Transformer Substation, Complete Switchgear and power transformers (below 35kV) passed the tests from CNAS, IAC-MRA, AL, CMA and others international testing organizations.